Subsection 9.27.2.3-1b of the "National Building Code of Canada 2005, Vol. 1

Subsection 9.27.2.3-1b of the "National Building Code of Canada 2005, Vol. 1 states: "The second plane (the drainage plane) of protection shall be designed and constructed to i) intercept all rain and snow that gets passed the first plane (the veneer) of protection and, ii) effectively dissipate any rain or snow to the exterior."

Real waterproofing involves real drainage

In his August 2010 article "Putting in Holes to Stop Leaks," Brett Newkirk wrote, "A wise Canadian once said, "It is amazing how many leaks you can stop by putting holes in a building." The holes referenced are weeps, but not just any weeps. Gone are the days of the "wicking" rope weep or the weep tube. If these old-style weeps worked at all, it was because some water leaked out of the moisture voids next to them and not through the weep itself. Many times, these antiquated weep devices weren't even placed at the lowest point in the wall. An effective weep must be placed at the lowest point in the wall (the bed joint of mortar). Weeps also need to be placed frequently to be effective. The channeled weeps in Figure 6 are placed 10 inches on center.

During the last 20 to 30 years, we have experienced myriad moisture-related problems in the building envelope. The increased use of rainscreen technology by designers has seen more than its share. Many reasons for moisture problems in the rainscreen building envelope exist. Some of the most frequent issues include: Tighter building envelopes increased mold and rot problem. Many modern materials created unintended moisture barriers. Increased insulation led to condensation problems.

View of entrapped moisture damage to materials in a rainscreen building envelope with no drainage.

BLOK-FLASH by Mortar Net USA

Through-wall flashing for single-wythe masonry walls. Saves installation time over conventional methods. Reduces thermal bridging, helping to maintain the wall's R-value integrity. Eliminates the need for multiple sizes of architectural CMU. Specified for many years by leading architects and retail chains.

800-664-6638 MortarNet.com

Makers of Mortar Net with Insect Barrier, TotalFlash", Blok-Flash, BlockNet', HouseNet, Stone & Stucco Drain", & Mortar Net Weep Vents.

Mortar Net USA LTD.


The Cornerstone of Success: Safety and Documentation in Masonry
April 2025

The masonry industry plays a vital role in constructing our homes, businesses, and infrastructure. Yet, beneath the enduring beauty of brick and stone lies a complex and often hazardous work environment. Ensuring the safety of workers and maintaining docu

How It's Made: Natural Stone Veneer
April 2025

Natural stone veneer is a durable, versatile, and aesthetically pleasing building material that has been used for centuries. It adds timeless beauty to masonry projects while offering structural integrity and resilience. But how does natural stone veneer

Vibing Masonry #5 - The Evolution of Concrete Masonry Units: From Ancient Foundations to Modern Innovations
April 2025

Early Development: The Genesis of Concrete Blocks (early Rome to 1900s) The history of concrete masonry units (CMUs) or concrete blocks begins with humanity’s earliest binding materials, notably the Romans’ remarkable concrete. Around AD 125, structures l

MASONRY STRONG Podcast, Episode 18 Recap: Jeff Tew, Westlake Royal Stone Solutions
April 2025

On this episode of the MASONRY STRONG Podcast, Jeff Tew joins the show, along with MCAA President Jeff Buczkiewicz, to talk about where his passion for this industry started and what it's been like working on the Supplier side of the industry. An Excitin